The number of module defects related to creepage distance has increased significantly in recent years following the introduction of M10R solar cells, according to solar technical advisors Kiwa PI Berlin.

Creepage refers to the minimum spacing required between components within a solar module to prevent short circuits, covering pathways such as cells to the glass edge, between adjacent cells and between cell strings. Chris Gabel, account manager at Kiwa PI Berlin, says adequate cell spacing is critical to module safety because cells placed too close can cause short circuits leading to thermal and electrical damage, and in the worst case can lead to a fire.

As the wafer market shifted toward larger M10R cells, manufacturers adopted them while maintaining the same glass and frame dimensions, meaning the only way to fit the cells was to reduce edge cell-to-glass, cell-to-cell and string-to-string spacing, often bringing these gaps close to or below minimum UL requirements. Gabel adds that dimensional tolerances of cells, glass and manufacturing equipment compound the problem, and manufacturers rarely consider the combined tolerance stack-up during the new product introduction process, making spacing difficult to control consistently in production.

Kiwa PI Berlin says several manufacturers either do not fully understand the safety standard requirements or the risks, and fail to classify the defects at an appropriate severity or set proper specifications. Addressing the issue requires industry-wide awareness plus clear acceptance criteria based on applicable UL and IEC requirements.

✦ This article was adapted by AI from public news sources for informational purposes only. It does not constitute investment advice.

LEAVE A REPLY

Please enter your comment!
Please enter your name here

- Advertisment -

Most Popular

Poland caps battery ramp rates in frequency reserve market from December 1

PSE's grid code changes limit aFRR ramp speed to control range divided by 2.5 minutes despite storage industry objections.

Intium completes 132 kV line three months early to unlock Gentari’s Maryvale project in NSW

The connection clears the path for a 243 MWp solar and 172 MW/409 MWh DC-coupled hybrid in New South Wales.

Juniper Green commissions 109 MWp hybrid solar in Maharashtra and 95 MWh BESS in Rajasthan

The additions lift the developer's operational portfolio to 2.95 GWp of renewables and 698 MWh of storage.

India’s open-access solar hits record 8.4 GW in 9M 2026 despite Q3 slowdown

Mercom India reports 29% annual growth as captive models and PPAs drive commercial and industrial demand.